Nova biomedical statstrip community, manuals and specifications. Meter must be placed in docking station when not in use a. Nova biomedical corporation, 200 prospect st, waltham, ma 024549141, united states. The purpose of this procedure is to outline the technique for operating the nova bedside glucose meter. Correctly enters operator id, lot number and patients id when performing a glucose test. Poct glucose testing using nova statstrip meter procedure version. Can cause undetected hypoglycemia can cause insulin overdose.
Pathology volume i poct and phlebotomy specimen collection, point of care testing waived tests, glucose nova stat strip hospital meter, poctw0, effective date. Based on the info received by the hospital b6 coordinator, staff managing a b6 pt located in the adult renal transplant section of the hospital attempted to utilize a nova statstrip glucose hospital meter to obtain a glucose reading. Lactate plus is a compact meter that measures whole blood lactate in seconds from a tiny, virtually painless blood drop. Point of care nova stat strip glucose meter the nova stat strip blood glucose meter is uhbs approved glucometer for patient testing operator certification status must be kept current use universal precautions when testing as per hospital policy follow patient identification procedures when testing as per. Oct 29, 20 the nova stat strip glucose meter reads results between 10600 mgdl a result reading higher than 600 will read as hi a result reading lower than 10 will read as lo any outofrange result will be displayed in red results within normal range 65115 will be displayed in blue. Nova statstrip glucometer maintenance and cleaning procedure. Statstrip operator training program slide presentation. Date opened and date expired expiration date is 180 days from opening or label expiration. The nova stat glucometer has been found to be reliable and accurate for the determination of blood glucose levels rabiee et al. Nova biomedical stat strip express ket test strips. Health care professionals hcps performing glucose and ketone poct using the nova statstrip glucose meter and nova statstrip glucoseketone meter. Bypass patient mrn entry in the nova statstrip glucose meter.
Nova biomedical statstrip glucose meter manualnova statstrip user manual one moment please. Poster session presented at the meeting of the american association for clinical chemistry, critical and pointofcare testing division, barcelona, spain. Nova statstrip user manual keyword found websites listing. Nova biomedical statstripstatstrip provides the analytical performance for those testing situations where glucose meter interface capability is not needed. Pocttraining and certification for the use of nova stat strip glucometers for nurses and muhc professionals within an. Statstrip hospital glucose monitoring system from nova. For export only nova statstrip xpressi glucose and. Could this device be used to effectively implement tight glycaemic. We have several locations in our facility that depend on multiport adapters. The nova statstrip meter must be used with nova statstrip glucose test strips. Nova statstrip glucose hospital meter system approved for use. Contact a supplier or the parent company directly to get a quote or to find out a price or your closest point of sale. Capillary, venous, arterial, and neonate whole blood. Nova blood glucose meter manuals manualslib has more than 2 nova blood glucose meter manuals.
The nova stat strip glucose meter reads results between 10600 mgdl a result reading higher than 600 will read as hi a result reading lower than 10 will read as lo any outofrange result will be displayed in red results within normal range 65115 will be displayed in blue. Please read it carefully before using your new monitor. Use of the nova statstrip blood glucose meter clinical. The staff attempted at least six readings using three different meters. Hospital blood glucose meter statstrip, statstrip xpress2. Two levels of quality control testing must take place. If a laboratory or the testing site modifies the test instructions, the test. Statstrip and statstrip xpress 2 glucose meters the only glucose meters cleared by us fda and health canada for use with all patients, including critically ill because of the unacceptably high rate of adverse patient events, including deaths, linked to the pointofcare poc use of glucose meters within hospitals, there is a recognized need for more accuracy and better performance. Wear gloves during blood glucose monitoring and during any other procedure that involves potential exposure to blood or body fluids change gloves between patient contacts. The glucose results are calibrated to agree with a method measuring. We are deciding wheather to use nova stat strip or the abbott system for our glucose point of care instrument. Nova stata strip glucose meter training cape fear valley the nova stat strip glucose meter reads results between 10600 mgdl a result reading higher than 600 will read as hi a result reading lower than 10 will read as lo any outofrange result will be displayed in red.
Refer to procedure to identify puncture sites and appropriate lancet. I need user manual for nova statstrip glucose dm meter fixya. A new class of analytical performance nova hospital glucose monitoring system nova biomedical headquarters. Nova stat strip the trainee must meet all of the following criteria in order to be certified for performing the point of care test. We have 1 nova biomedical statstrip xpressi manual available for free pdf download. All test strips and control bottles must be dated with the open. This procedure provides instructions for troubleshooting the nova statstrip meter by. The nova statstrip hospital glucose monitoring system is the only glucose meter system cleared by the fda for use with critically ill patients. Nova statstrip glucose meter reagent requirements nova statstrip glucose test strips nova statstrip glucose control solution storage temperature room temperature nova biomedical. Nova statstrip glucose meter reagent requirements nova statstrip glucose test strips nova statstrip glucose control solution storage temperature room temperature nova statstrip blood glucose meter clinical guideline v3. Nova biomedical develops, manufactures, and sells advanced. The meter either reports glucose results in mgdl, 43404, or mmoll, 44321, and can not be changed. It incorporates a new strip technology that uses four measuring wells. Nova biomedical instructions for use manual, printed in the u.
These sessions are primarily aimed at new users, but you can attend for an update if required. Nova biomedical statstrip quick reference manual pdf. Nova s multiwell system measures and corrects hematocrit interference, as well. Intended use the nova statstrip lactate hospital meter system is intended for in vitro diagnostic use by health care professionals for clini cal and for pointofcare usage for the quantitative determina tion of lactate lac in fresh whole blood venous and arterial blood samples. Whether testing is performed in the central laboratory or in emergency, surgical, critical, or respiratory care areas, nova analyzers can help to improve patient outcomes while reducing the cost of care. Ketone hospital meter system statstrip is intended for measuring glucose in fresh capillary, venous, or arterial blood including neonate blood, by health care professionals. Glucose is measured amperometrically, using an enzyme based test strip. Blood glucose monitor nova biomedical statstrip forums. Nova hospital glucose monitoring system a new class of. Nova stata strip glucose meter training cape fear valley health. Hemoglobin heemoglobin is the part of a red blood cell that carries oxygen to the cells and sometimes joins with the glucose in the bloodstream. Like the statstrip glucose hospital meter, statstrip xpress elevates bedside glucose testing to a new level of analytical performance that approaches the quality of central laboratory testing. Statstrip glucose meter rapidly becoming standard in accurate. Nova biomedical statstrip quick reference manual pdf download.
Nova thanks you for choosing the nova max blood glucose monitor. Contain a desiccant to protect against humidity must be closedwith its lid when not in use store at room temperature between 15 to 40 degrees centigrade 59 to 104 degrees fahrenheit when opening a new vial of strips, write on vial. Statstrip glucose hospital meter system receives fda clearance for capillary testing with critically ill patients only glucose meters with fda clearance for use with all patients including critically ill clia waived for use with arterial, venous, and capillary samples from critically ill patients only glucose meter with no known clinical interferencesover 8,000 medications tested measures. Laxenburger strasse 336, a1100 vienna, austria tel. Nova statstrip glucose meter johns hopkins pathology. Evaluation of the nova statstrip glucometer in a pediatric hospital setting. Statstrip meter first introduced in may 2006, by nova biomedical. The point of care testing procedure manual contains the approved procedures for safe and effective operation of poct procedures by mgh poct providers. Test strips should be stored in original vial tightly clos. Any paper document labeled uncontrolled must be verified against the. Pdf accuracy and reliability of the nova statstripr. Nova biomedical statstrip xpressi manuals manualslib. The nova max blood glucose monitor is designed to be convenient and easy to use.
Clean the meter with a cloth that has been dampened with a 10% bleach solution or see manufacturers approved cleansing solution list. It is not for diagnosis of, or screening for diabetes. New stat strip glucose meter and strips chosen for province wide implementation. Statstrip glucose meter rapidly becoming standard in accurate hospital glucose testing throughout usa and now canada.
Statstrip xpress 2 glucose hospital meter system common or usual name. Nova statstrip glucose meter data sciences international. One of statstrips four measuring wells measures hematocrit. Nova statstrip glucometer maintenance and cleaning. The meter must be level or strip angled downward j. Statstrip xpress 2 glu nova biomedical corporation. Nova biomedical statstrip xpress community, manuals and. We have remained at the forefront of medicine by fostering a culture of collaboration, pushing the boundaries of medical research, educating the brightest medical minds and maintaining an unwavering commitment to the diverse communities we serve. About this manual this manual is for the nova biomedical statstrip xpress glucose hospital meter. Nova also provides handheld meterandstrip based measuring systems for glucose, ketone, lactate, and creatinine pointofcare testing. This manual provides all necessary instructions for the routine operation and maintenance of the nova statstrip xpressi glucose and. A guide from the statstrip manual is reprinted in attachment 1. Nova biomedical stat strip express for ketonemia blood glucose meter.
Statstrip also showed improved sensitivity for detecting critical low glucose values. Poct nova stat strip glucometer clinical instructor document. It has been prepared to help you attain optimum performance from your meter. Clinical impact of improved pointofcare glucose monitoring. Statstrip glucose has no known interferences and brings lablike accuracy to bedside glucose testingaccuracy validated in an fda submission study of 1,698 critically ill patients with 257 different and specific medical conditions, and over 8,000 medications, as well as over 7 published studies throughout the world. Nova biomedical hospital based blood gas and critical care analyzers hospital glucose measuring system only glucose meters accurate enough to be fdacleared for use with all patients, including critically ill only glucose meters cleared by the fda for use with all patients, in all professional healthcare settings, including critical care eliminates interference which cause incorrect. November 30, 2020 december 01, 2020 november 30, 2024. Point of care testing page nova statstrip and the statstrip xpress glucose meter 3101. Immediately following the appropriate wet contact time of. Nova statstrip xpress glucose hospital meter instructions for. Statstrip glucose xpress2 meter from nova biomedical. Blood lactate meter for sports training and conditioning. Nova statstrip glucose meter training fast facts revised 42020.
The statstrip lactate hospital meter refer to this quick reference manual only after you have become familiar with all of the instructions in the instruc tions for use manual. Unit of measure information the unit of measure of the statstrip xpress glucose hospital meter is factory set to the standards in the country of use. Statstrip is the only bedside glucose meter to measure and eliminate glucose errors due to varying hematocrit levels. Site is clean, use of antiseptic, discard first drop. Nova biomedical statstrip xpress accurately monitor blood glucose levels that. Laboratoryclinical guidelinestandard operating procedure. Statstrip glucose xpress2 meter from nova biomedical description statstrip glucose xpress2, along with statstrip glucose and statstrip glucose xpress are now the only three hospital glucose meters to be cleared by the fda and proven to be safe and effective for use throughout all hospital and professional healthcare settings, including. Instructions for use manual nova biomedical statstrip xpressi instructions for use manual 82 pages glucose and bketone hospital meter. Immediately following the appropriate wet contact time of the disinfectant wipe use a. Find out all of the information about the nova biomedical product. Nova statstrip xpress glucose hospital meter instructions. Nova stata strip glucose meter training cape fear valley. Insert the gold end of the test strip into the meter strip port with the statstrip label facing upward. This owners guide contains important information on the monitor and how it works.
If the patient does not have a wristband or a barcoded sticker in their notes, then please manually enter the. Nova statstrip glucose hospital meter system approved for. Scanhome buttons test strip port one on each side touch screen. Use of the nova statstrip blood glucose meter clinical guideline v3. Statstrip glucose has no known interferences and brings lablike accuracy to bedside glucose testingaccuracy validated in an fda submission study of 1,698 critically ill patients with 257 different.
744 1439 777 1687 677 1306 1391 290 1457 1236 305 1773 191 135 671 228 956 298 1044 491 1249 1113 761 1497 139 615 121 469 1355 1186 584 161 1603